Home ProductsElectric Vehicle Charging Station

Strength Resistance 3000W On-board DC / DC Converter 200 - 750Vdc For Electric Vehicles

Strength Resistance 3000W On-board DC / DC Converter 200 - 750Vdc For Electric Vehicles

Strength Resistance 3000W On-board DC / DC Converter 200 - 750Vdc For Electric Vehicles

Product Details:

Place of Origin: China
Brand Name: Goldpower
Certification: UL/CE/ROHS/FCC/SGS
Model Number: GPEV-DD302M-H-N-1A

Payment & Shipping Terms:

Minimum Order Quantity: 200pcs
Price: negotiation
Packaging Details: 1 unit in 1 colorful box, 6 boxes in one master carton
Delivery Time: 40 working days on payment
Payment Terms: T/T
Supply Ability: 30,000pcs per month
Detailed Product Description
Application: Electric Vehicle Input Range: 200-750Vdc
Output Range: 3000W(Max3600W) Standard: UL/CE/ROHS/FCC/SGS
Ventilation: Systems Integration Cooling Dimensions: 316mm*211mm*84mm

200~750Vdc 3000W onboard DC/DC Converter for Electric Vehicles

 

Specification

1.1 Environmental

Parameter Min Typical Max Unit Remarks
Working temperature -40   +85 °C Auto derating, T≥ 85°C
Storage temperature -40   +105 °C  
RH 5   95 %  
Altitude 0   3000 m  
Cooling Systems integration cooling
Water/dust proof level IP00

 

1.2 Input

Parameter Min Typical Max Unit Remarks
Input voltage range 200   750 Vdc  
Rated voltage range 540 Vdc With input reverse protection
Max voltage     14 A 250Vdc input, full load
Static current loss   1 2 mA  

 

1.3 Output

Parameter Min Typical Max Unit Remarks
Rated voltage 27 Vdc Rated input, output half load
Rated output voltage 27±0.3 Vdc
Current range 0   110 Vdc Input voltage <250V, output current derating. (110A/250V-55A/200V)
Max current 110 A Max working current for long time operation
Rated power 3000 W  
Output peak power 3600 W  
Efficiency   96   %  
Temperature Coefficient     ±0.02 %/°C  
Noise and ripple     300 mVp-p Oscilloscope bandwidth of 20 MHZ, 10 u + 104 cap paralleled with a probe
Time of start-up     3 S  
Output rising time     300 ms  
Voltage stability     ±1  
Load regulation     ±1  
Static current loss     1 mA Without connecting high voltage and 24 VDC, output connecting with 24VDC battery leak current.
Control method CAN or EN
Dynamic response of voltage overshoot     ±3 % 0%~70%~0% or 50%~120%~50% load change, Load mutation rate≤0.1A/us, load dynamic frequency 50Hz-5KHz.
Capacitive load 4500   45000 uF Ordinary aluminum electrolytic capacitor
Continued input on/off Supporting continuous input on/off. Under the condition of given control signal and normal output, able to endure 5x continued on/off within 1min, no malfunction or damage to the power supply.

 

1.4 Protection against

Parameter Min Typical Max Unit Remarks
Input over-voltage 760   810 Vdc  
Over-voltage recovery 750   800 Vdc  
Input low-voltage 170   190 Vdc  
Low-voltage recovery 180   200 Vdc  
Output over-voltage 31   33 Vdc Auto recovery, output flow backwards 50Vdc without damage.
Output low-voltage 18.0   19.0 Vdc Auto recovery
Over-current 1. If input voltage >250V, output current 110~136A, the unit is able to continuously operate full load for 6min, and then current limiting point drops to 110A. 2. When Input voltage drops from 250V to 200V, output current limit also linearly drops from 110A to 55A.
Over temperature T>85°C, output derates linearly. T>95°C, output shut down. T<80°C,output auto recovers.
Output short-circuit Auto recovery when fault removed
Input reversed No damage if reversed
Input energizing sequencing
  1. High voltage before control signal 2. Control signal before high voltage. 3.High voltage and control signal at the same time. Power supply works normally, no protection triggered on damage caused.

 

1.5 EMC

Parameter Standard requirement
EMI
EMC GB_T 21437.2-2008 Positive limiting:50V Negative limiting;-50V Test port:(1)Input 24V,(2)Output 24V
CE GB_T 18655-2010 Level 3.Test port:(1)Input 24V,(2)Output 24V,(3)High voltage input
RE GB_T 18387-2008 Level 3 with system testing
EMS
ESD GB/T 19951-2005 Whole machine(power on) contact discharge:±6KV,Air discharge:±8KV,criterion:B.Whole machine( not power on) contact discharge: Air discharge±6KV:±15KV criterion:C
Radiated electromagnetic field immunity free field method GB/T 17619-1998 whole machine 100V/m criterion:A
BCI GB/T 17619-1998 high voltage input,24V input ,24V output 100mA,criterion: A
Conductive interference along lines (24V) GB_T 21437.2-2008(ISO 7637-2) Level 4, criterion:A
EFT GB_T626.4-2008(IEC61000-4-4) high voltage input:±4KV,5KHz/100KHz,+24V input ,+24 output ±2KV,5KHz/100KHz.,criterion:B
EMS remarks: based on output voltage and current stability.

 

1.6 Auxiliary

Parameter Standard requirement
Low temperature test GB/T 2423.1
High temperature test GB/T 2423.2
Vibration 5.91Grms,32 h/axial(Normal connection and fixed wiring harness,ISO16750-3,2012(E)
Percussion test 500m/ S2,half sine wave,6ms,ISO6750 4.2.2.2
MTBF ≥400000H

 

1.7 Safety and insulation class

Parameter Standard requirement Remarks
Electrical strength resistance (Input /Output) 2500Vdc Withstand 2500Vdc for 1 minute, leakage current ≤1mA, no breakthrough or arcing.

Insulation resistance

(Input /Output)

≥20MΩ Input to output, Input to case, applying 1000 VDC at 1 atm, RH 90%.
Charge discharge capacity ≤36V In ten minutes after DC/DC powered off

 

1.8 Mechanical

Dimensions 316mm*211mm*84mm
Weight ≤2.5Kg

 

Contact Details
Shenzhen Techone Tech Co.,Ltd

Contact Person: Vivian

Send your inquiry directly to us (0 / 3000)