Home ProductsElectric Vehicle Charging Station

750V 120KW Electric Vehicle EV Charger Station With High Performance / Reliability

750V 120KW Electric Vehicle EV Charger Station With High Performance / Reliability

750V 120KW Electric Vehicle EV Charger Station With High Performance / Reliability

Product Details:

Place of Origin: China
Brand Name: Goldpower
Certification: UL/CE/ROHS/FCC/SGS
Model Number: GPDC750V160-HA

Payment & Shipping Terms:

Minimum Order Quantity: 200pcs
Price: negotiation
Packaging Details: 1 unit in 1 colorful box, 6 boxes in one master carton
Delivery Time: 40 working days on payment
Payment Terms: T/T
Supply Ability: 30,000pcs per month
Contact Now
Detailed Product Description
Application: Electric Vehicle Input Range: 265~437Vac
Output Range: 300~750Vdc Cooling: Compulsory Ventilation
Dimensions: ≤165Kg(with Power Module) Weight: ≤95Kg(cabinet + Distribution, No Power Module)

750V 120KW Electric Vehicle Charging Station with high performance and reliability
 
Technical specifications:

Environmental
Parameter Min Typical Max Unit Remarks
Working temp. range -20 25 55 °C For safety regulation and certificate
Extreme. Temp. range -40 25 60 °C

-40°C ~-20°C, works loads.

55 -60°C, works with 4%/°C linear derating ouptut

RH 5   95 % No condense
Altitude 0   2000 m  

 

Input
Parameter Min Typical Max Unit Remarks
Input mode 3-phase / 5-wire No neutral wire
Rated voltage range 323 380 437 Vac For safety regulation and certificate
Start-up voltage range 306   505 Vac With full load
Working voltage range 265 380 437 Vac 315-265Vac, 15KW linear derates to 5kW with step 2%/V
Max voltage     560 Vac Not working, No failure
Max current     240 A Low voltage with full load, per phase
Max power     128 KW Input 323Vac/ output full load
Time of soft start-up 5   15 S Time from plug-in to voltage rising to rated value
PF >0.99 Rated input, full output
>0.98 Rated input, half output
THD THD<5% Rated input, full output
THD<10% Rated input, half output
GND Housing case grounded

 

Output
Parameter Min Typical Max Unit Remarks
Rated voltage 750 Vdc  
Voltage range 300   750 Vdc For safety regulation and certificate
Rated current 20   160 A With single-charger mode, #1 or #2
10   80 A With double-charger mode, #1 or #2
Rated power     120 KW  
Voltage stability -0.5   +0.5 %  
Ripple RMS     1 %  
Dynamic response time     200 us  
Dynamic response overshoot -0.5   +0.5 %  
Efficiency     95.8 %  
Noise     65 dB(A)  
Current-sharing unbalanced rate     5 % output current > 50%
Cooling Compulsory ventilation

 

Protection against
Parameter Min Typical Max Unit Remarks
Input over-current Functioned by circuit breaker with plastic housing
Input over-voltage 455   465 V  
Over-voltage recovery 445   455 V  
Input low-voltage 250   264 V  
Low-voltage recovery 280   305 V  
Overheated   57   °C Auto recovery when cooled down
Output over-voltage 765   780 V Manual recovery
Output over-current     164 A Constant current when over current
Output short-circuit  
Fan failure Each every fan stops, the whole system stops.
Battery reversed No output when battery reversed
Insulation Automatic insulation test
System error During the charging process, the system will immediately stop working and break out the contactor for any emergency (Emergency switch triggered, BMS communication error, Control guiding error, etc.), and lower down the charger voltage to 60Vdc or less within 1s.

 

Auxiliary
Parameter Min Typical Max Unit Remarks
Output current tolerance -1   1 % Current <30A with +/-0.3A tolerance
Output voltage tolerance -0.5   0.5 %  
DC meter tolerance   0.5   level  
Low voltage Aux power supply   24±1%   Vdc Optional 20A
  12±1%   Vdc Optional 10A
Charger cord length   5±0.2   m  
Charger type GB/T20234.3-2015

 

Insulation
Parameter Requirement Remarks
Input /Output 3535Vdc/10mA//1min No break-through or arcing for 1 min at 1 atm
Input/Case 3535Vdc/10mA//1min
Output/Case 2121Vdc/10mA//1min
Insulation When 1 atm, RH≤90%, insulation resistance under 1000Vdc > 10MΩ.

 

EMC
Parameter Requirement Standard
ESD Air discharge±8KV GB/T 17626.2-2006(Criteria A)
Contact discharge±6KV
RS Frequency: 80MHz~1000MHz; 800MHz~960MHz,1.4G~2.0GHz, EFI: 10V/m; Amplitude modulation : 80%AM(1KHz) GB/T 17626.2-2006(Criteria A)
EFT/B PE: 2KV GB/T 17626.4-2008(Criteria B)
SURGE 2KV±10% GB/T 17626.5-2008(Criteria B)
CE CLASS A EN55022
RE CLASS A EN55022

 

Mechanical
Dimensions (L×H×W)700 mm×1800 mm×600mm
Weight

≤165Kg(with power module)

≤95Kg(cabinet + distribution, no power module)

 

Power module spec

Parameter Unit Min Typical Max Conditions
AC input voltage Vac 323 380 437  
Frequency Hz 45 50/60 65 With rated load
PF   0.99     With rated voltage/load
Input voltage range Vdc 300   700  
Output current A 0   20  
Output voltage stability       ±0.5%  
Voltage peak-to-peak %     1 With 1x0.1uF ceramic cap and 1x10uF E-cap, testing bandwidth=20MHz
Output power KW 0   15  
efficiency %     95.8  
Input over-voltage protection trigger Vac 455   465 Automatic recovery
Input over-voltage recovery trigger Vac 445   455  
Input low-voltage protection trigger Vac 250   264 Automatic recovery
Input low-voltage recovery trigger Vac 280   305  
Output over-voltage protection trigger Vdc 765   780 Manual recovery
Output over-current protection trigger A     20.5 Constant current output when over current
Short-circuit protection A Automatic recovery
Overheated protection   Automatic recovery at ambient 55C

 

Smart Features :
AC & DC charging , easy maintenance , stable
 

 

Contact Details
Shenzhen Techone Tech Co.,Ltd

Contact Person: Michael

Tel: +8613603082685

Send your inquiry directly to us (0 / 3000)